What Size Hole for Romex?

Hunker may earn compensation through affiliate links in this story. Learn more about our affiliate and product review process here.
House wiring is best done before the walls are completed.

House wires are frequently run through both vertical framing members, such as wall studs and window cripples, or through horizontally-placed floor and ceiling joists. Circular holes are drilled in the wood to allow the wire to pass from one side to the next.

Advertisement

Structural Considerations

Video of the Day

Since most electrical codes no longer allow 14 gauge house wire in new construction, 12/2 gauge wire with a ground is predominantly used in most residential wiring circuits. Hole size through a joist (2-by-6 or larger) is usually limited by building codes to 1/3 of the board depth, which provides for ample room when pulling wires. However, vertical 2-by-4s pose different challenges for pulling wires.

Advertisement

Video of the Day

Large Holes

The larger the hole for the ROMEX® wire the better off you are, as long as you don't compromise the structural integrity of the 2-by-4. If you go by the 1/3 rule, then 1 1/8 diameter is the maximum diameter, but that only gives the wire 1 1/8-inch protection from nails and wall board screws. One-inch or 3/4-inch holes would be better.

Advertisement

Pulling Wires

The biggest danger of using small holes in home wiring is damaging the wire when installing the cable. Therefore, hole size should be somewhat roomy, so as to accommodate two or three wires, passing through the same hole. Seven-eighths inch is actually the most common wire hole found in 2-by-4 framing.

Advertisement