Radiator Heating Problems

Save

Steam-heat boilers and radiators are old ideas that still keep dwellings warm and cozy through cold winters. Their operation is simple and usually reliable, but a few things can go wrong. There's a short list of breakdowns and basic maintenance issues that can cause one or more radiators to lose their heat, leak water or operate noisily. When unsure of the cause, it's best to contact a qualified technician to examine the entire system.

No Heat from a Single Radiator

  • If the single radiator is not heating up, there could be air trapped in the radiator. When the radiator is cool, open the bleed valve at the top of the radiator; close again when water begins leaking or squirting from the valve. You might also have a faulty or clogged inlet valve at the radiator foot. The water pipe leading from the floor to this valve and then to the radiator baffles should be hot to the touch. If the pipe between the valve and the radiator is cold, the valve itself could be clogged or stuck in the closed position. Clogged valves should be replaced.

No Heat from a Boiler

  • You might have a tripped circuit breaker. Check the service panel or fuse box and reset the breaker or replace a blown fuse. Make sure the boiler's water level is correct by checking the water pressure, which should be between 12 and 15 pounds per square inch (psi). If the pressure is too low, open the fill valve until the pressure reaches 12 psi. Also check the pilot light, which may be out, or the electronic ignition if there is no pilot. Finally, check to make sure the thermostat is set to "heat," then try to reset the temperature.

Heat has Gradually Lessened

  • Check that water pressure in the boiler has not fallen below 12 psi, which could be caused by a leak. The expansion tank may be overfilled or mineral deposits may have built up in the boiler or water lines. A technician can check for and repair water leaks, check the expansion tank or flush the system out, if necessary.

Water on the Floor near Boiler

  • Water on the floor near the boiler could be a sign of a faulty circulator pump, faulty pressure valve or leaking pipes. A technician can repair the circulator or replace the pump seal. The pressure valve may also be fouled with sediment. This can be checked by turning off the boiler and operating the pressure relief lever. If water continues flowing after closing the lever, or no water is discharged at all, the valve should be replaced. Leaks can also be revealed through a visual inspection of the pipes and connections. Replacing rusted out or leaky pipe connections is for professionals.

Water on Floor Near Radiator

  • The cap nuts used to fasten the inlet valve may have come loose or be corroded. Turn the system off, then tighten the valve nuts; it this doesn't work, replace them.

Banging and Clanging Pipes

  • The coupling that links the circulator pump to the motor may be broken. Or, there may be a problem with the angle of the water return lines. Steam in the radiators condenses, then returns to the boiler via a downward-sloping pipe. The radiator should be angled slightly back towards the inlet pipe. This can be easily corrected by placing a shim or wedge of wood underneath the far end of the radiator. Also check the inlet valve to make sure it is completely open.

References

  • Photo Credit Image by Flickr.com, courtesy of r-z
Promoted By Zergnet

Comments

You May Also Like

  • Hot Water Heating System Problems

    Hot water heating systems, also called hydronic systems, use water heated in a water heater or boiler as the heating medium, which...

  • Buick Rendezvous Heat Problem

    Introduced in 2001, the Buick Rendezvous is a crossover SUV manufactured by General Motors. The Buick Rendezvous can develop a number of...

Related Searches

Check It Out

22 DIY Ways to Update Your Home on a Small Budget

M
Is DIY in your DNA? Become part of our maker community.
Submit Your Work!